亚洲毛片在线精品观看_網友分享99爱在线精品视频网站心得_在线观看a网站_污色视频免费网站_四虎影院久久久_國產歐美精品三區_一级少妇淫片免费放_国产亚洲vs无码中文_国产一级黄色免费电影_www嗯啊一区二区

中文 EN
Return
Categories
SDCBUS series power battery performance testing system SDCBUS-2400/100-500-1CD
SDCBUS series power battery performance testing system SDCBUS-2400/100-500-1CD

SDCBUS series power battery performance testing system SDCBUS-2400/100-500-1CD

The SDCBUS series power battery performance testing system is a high-precision AC/DC power processing system independently developed by Zhuhai Jiuyuan. The system utilizes the bidirectional characteristics of power facilities to meet the unidirectional and bidirectional transmission needs of loads, achieve grid control of power supply, eliminate resistance load consumption, and significantly reduce energy loss.
Product details

Product Introduction

The SDCBUS series power battery performance testing system is a high-precision AC/DC power processing system independently developed by Zhuhai Jiuyuan. The system utilizes the bidirectional characteristics of power facilities to meet the unidirectional and bidirectional transmission needs of loads, achieve grid control of power supply, eliminate resistance load consumption, and significantly reduce energy loss. This system can be widely used for electrical performance testing of various types of batteries such as lithium batteries, lead-acid batteries, and special liquid batteries, as well as aging testing of electronic loads.


Product Features

Patent technology topology structure, optimal energy-saving control

Wireless connection design for core inverter module, stable and reliable, worry free in the future

Long life accessory selection, system design service life of one5+years

No phase sequence restriction * intelligent lock-in, flexible and efficient

Pure sine wave grid connected control technology, no grid pollution

Automated testing and management, low threshold efficiency improvement solution

 

Application scenarios

Battery module PACK、 Cluster electrical performance testing:

Battery pack capacity test

Battery pack charge/discharge characteristic test

Battery pack charging/discharging efficiency test

Battery pack charge retention and recovery capability test

Cycle life test of battery pack

 Temperature characteristic test of battery pack

DC internal resistance test of battery pack

Pulse charging/discharging test for battery pack

Simulation test of battery pack operating conditions

 Test on the ability to withstand overcharging and overdischarging rates of battery packs


Electronic load function:

Aging energy feedback of DC power supply:

DC to AC power grid+intelligent aging testing - efficiently invert DC power into AC power and feed it back to the grid, reducing traditional load heat loss; Synchronize simulation of equipment aging conditions to achieve low energy consumption, high-precision DC equipment life testing and energy recycling.


Battery simulation function

High precision battery charging and discharging simulation:

High precision reproduction of battery charging and discharging curves, supporting dynamic operating conditions and fault simulation; Energy feedback>96%, reducing testing energy consumption and synchronously verifying performance and security.


Typical equipment parameters and models

Project name

Typical equipment model parameters

Notes

Equipment model

SDCBUS-100/010-100-12CD

SDCBUS-750/030-100-4CD

SDCBUS-1000/050-300-2CD

SDCBUS-1500/050-300-2CD

SDCBUS-2400/100-500-1CD


Equipment appearance (length * width * height/mm)

1140*950*1900

1140*950*1900

2280*1200*1900

2840*1200*1900

4280*1200*1900

 

Equipment weight (kg)

1000

1300

2660

4200

5400


Number of channels per device

12

4

2

2

1

The number of channels can be customized

Single channel rated power (kW)

10

75

300

450

1200

Support full power output

Single device rated power (kW)

120

300

600

900

1200

Support full power output

Output voltage range (V)

10~100

30~750

50~1000

80~1500

100~2400

Supports 0V charging

Accuracy of output current and voltage a

±(0.05%FS+0.05%RD)

Other high-precision requirements can be customized

Energy feedback mode

The device adopts patented technology of common DC bus internally, and energy is preferentially recycled between the DC side channels.

Energy feedback efficiency

≥92%

≥97%

≥96%

≥97%

≥96%

Full load charging or discharging.

Maximum efficiency of internal circulation

≥94.5%

≥98%

≥97.5%

≥98%


Channel charging and discharging

Grid side parameters

rated operational voltage

AC 380 V ± 15% (three-phase five wire system), grounding resistance value ≤ 5 Ω

Input voltage can be customized

Operating Frequency

50/60±2Hz


Power factor

≥0.99

More than half a year

Current Harmonics (THD)

≤3%

fully loaded

input protection

Overvoltage, undervoltage, overload protection, phase loss protection, lightning protection, islanding effect, etc

Battery side output

parallel mode

Supports parallel connection of continuous channels, with a maximum of 10 channels per group in the same cabinet for parallel connection


Current response time

≤5ms

10%~90% (battery load)

Charge discharge switching time

≤10ms

+90%~-90% (battery load)

Continuous sampling interval

≤10ms

Including current and voltage acquisition

Output voltage resolution

0.1mV


Output current resolution

0.1mA


Output power resolution

0.1W


Output Protection

Undervoltage, overvoltage, short circuit, overheating, reverse connection, overcurrent, communication abnormality, power outage, emergency stop, etc